The ASTM E (Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure. Imison. John H. Waskow, P.E.. Architectural Testing, Inc. Test Method: ASTM E , Test Method for Water Penetration of Exterior Windows, Curtain Walls. Purchase your copy of ASTM E – 00() as a PDF download or hard copy directly from the official BSI Shop. All BSI British Standards.

Author: Kishicage Kigalar
Country: Uruguay
Language: English (Spanish)
Genre: Art
Published (Last): 8 December 2017
Pages: 110
PDF File Size: 18.92 Mb
ePub File Size: 3.58 Mb
ISBN: 262-8-23882-356-9
Downloads: 99702
Price: Free* [*Free Regsitration Required]
Uploader: Vikus

Professional services based on accurate information that helps you or your company make the right decision regarding your project or asset.

This field water check method is not intended to test the rated or specified water performance representative of a wind driven rain event.

The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. Specifically excluded from this field check method is the testing of operable components such as operable window and doors.

This starts with a clearly defined sequence of activities that SITC follows during a investigation: The ASTM E Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference is a testing standard that describes the procedures to determine the water penetration resistance of windows, curtain walls, skylights, and doors when water is applied using a calibrated spray apparatus while simultaneously applying uniform static pressure to opposite sides of the test specimen.

BDG has extensive knowledge of most building 000 and specializes in forensic water intrusion investigations. Analyzing the data and establishing a cause and effect relationship between wall characteristics and the observed leakage. There are two different procedures listed for the test method.

Water Penetration Field Testing

This test method does not address these issues. The evaluation of the design concept to determine if any water resistance performance requirements were specified for the wall. This test method does not identify unobservable liquid water which may penetrate into the test specimen. Read more about what our customers have to say The diagnostic field water check is utilized for installed storefronts, curtain walls and sloped glazing systems only.

  GY-HM150 JVC PDF

For specific hazard statements, see 7. Procedure B is a cyclic static air pressure difference. This allows us to not only properly test fenestrations on new construction projects, but also pinpoint the cause of any test failures and provide accurate recommendations to achieve successful testing results.

If you are looking for a reputable second or third-party testing company to perform accurate professional testing, provide concise reports, and help you through the entire process, contact BDG today.

ASTM E | Water Penetration Testing

ASTM states that the field test may be made at the time the window, skylight, curtain wall or door assemblies are initially installed. SITC e313 what procedure to utilize based on the laboratory testing results.

In service, the performance will also depend on the rigidity of supporting construction and on the resistance of components to deterioration by various causes, vibration, thermal expansion and contraction, etc. The calibrated spray apparatus spray-rack system delivers water to the test specimen at a rate of 5. Some designs are more sensitive than others to this upward asrm water.

Historical Version s – view previous versions of standard. This test method exclusively utilizes a uniform static air pressure difference. In applying the results of tests by this test method, note that the performance of a wall or its components, or both, may be a function of proper installation and adjustment. The aastm objective of forensic water testing is to identify the leak paths through the simulation of the weather events that produced the reported leakage.

Our field consultants are properly trained and knowledgeable of all testing standards. Conducting the investigative testing to verify and extend hypotheses arrived at during the document review and inspection portions of the investigation using e331 and reproducible procedures. The purpose of this voluntary guideline is to recreate leaks that are known to occur. This standard is utilized for laboratory or interior mock up testing only. The reviewing r331 project documents for the building.

  HP OFFICEJET PRO K850 SERVICE MANUAL PDF

The testing pressure differential is usually determined by the testing e3311. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM E331 – 00(2016)

BDG utilizes professional testing equipment that is calibrated to each specific testing standard for accurate results. The air-pressure differences acting across a building envelope vary greatly. Most generic specifications call for a minimum testing pressure of 6. The AAMA is the proper test method w331 field testing of storefronts, curtain walls and sloped glazing for air leakage resistance and water penetration resistance performance.

This specification is for quality assurance testing only of storefronts, curtain walls and sloped glazing systems and their installation. Give us a call to discuss your next project. Which would be referred to as quality assurance testing. ASTM states the field test may also be made after the building is completed and in service to determine whether or not reported leakage problems are due to the failure of the installed assemblies.

ASTM E references the following documents: The AAMA describes steps for calculating the approximate differential air pressures the specimens experienced during actual wind driven rain events. We provide testing services throughout the Sstm States ee331 our headquarters located in Atlanta, GA.

Specifically excluded from this specification are windows, glass doors and skylights. The ASTM E testing is performed by applying water to the exterior of the test specimen while xstm the pressure inside by means of an air chamber built on the inside or opposite side of the test specimen. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Link to Active This link will always route to the current Active version of the standard.