ASTM C1611 PDF

ASTM C1611 PDF

ASTM CCM 14 Standard Test Method for Slump Flow of Self- Consolidating Concrete_建筑/土木_工程科技_专业资料。Designation. Testing. • Visual Stability Index (VSI). – Based on slump flow test – ASTM C • Column Segregation Test – ASTM C • Penetration Test – ASTM C Download scientific diagram | The slump flow test (ASTM C). from publication: Correlations between Compressive, Flexural, and Tensile Behavior of.

Author: Jushura Daihn
Country: Poland
Language: English (Spanish)
Genre: Technology
Published (Last): 17 January 2007
Pages: 500
PDF File Size: 9.97 Mb
ePub File Size: 4.27 Mb
ISBN: 371-6-15106-400-6
Downloads: 72928
Price: Free* [*Free Regsitration Required]
Uploader: Mishakar

ASTM D standar A number in parentheses indicates the year of last reapproval. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other.

Combining values from the two systems may result in non-conformance with the standard. These notes and footnotes excluding those in tables and? It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure. Current edition approved April 1, Originally approved in Summary of Test Method 4. The concrete is placed in one lift zstm tamping or vibration.

The mold is raised, and the concrete is allowed to spread. After spreading ceases, two diameters of the concrete mass are measured in approximately orthogonal directions.

ASTM C Standard

Therefore, this test method is considered applicable to self-consolidating concrete having coarse aggregate up to 25 mm [1 in. Appendix X1 provides non-mandatory visual astn criteria that may be used to classify the ability of a self-consolidating concrete mixture to resist segregation stability.

Appendix X1 provides a non-mandatory procedure that may be used to provide an indication of relative viscosity of self-consolidating concrete mixtures. No further reproductions authorized. The provision of a collar sstm the top of the mold is useful to reduce the probability of concrete spilling over the mold and on to the base plate.

  FR107 DIODE DATASHEET PDF

Other users preferred to place astmm mold with the smaller opening face down, which facilitates the ease of? The precision statement in Section 10 re?

Test data using the two? NOTE 4—As a precaution, when? Experienced users of this test method have found that it is not necessary to support the mold. NOTE 2—A pouring vessel with a pouring lip is useful aetm reducing the probability of concrete spilling while? Use a base plate in conditions where a? When the base plate is used, position and shim the base plate so that it is fully supported.

Dampen the work surface, removing any standing water. Do not subject the work surface or mold to c11611 or disturbance. Position the lowest point on the rim of the pouring vessel no more than mm [5 in. Ensure an even distribution of concrete, without rodding the concrete or tapping the sides of the mold, while? Remove concrete from the area surrounding the base of the mold to preclude interference with the movement of the?

Remove the mold from the concrete by raising it vertically. Raise the mold a distance of 6 75 mm [9 6 3 in. Complete the entire test from the start of? When a halo is observed in the resulting circular spread of concrete, it shall be included as part of the diameter of the concrete. Measure a second diameter d2 of the circular spread at an angle approximately perpendicular to the? Measure the diameters to the nearest 5 mm [1?

Precision and Bias4 The round robin test program consisted of using single and multiple operators performing 3 replicas of the test using the mold in both asstm upright and inverted positions.

The tests were performed using ast concrete with high and low levels of slump? The single-operator standard deviation for slump? Therefore, results of two properly conducted tests by the same operator on the same batch of concrete should not differ by more than 75 mm [3. The multi-operator standard deviation for slump? Therefore, the results of properly conducted tests by two operators on the same batch of concrete axtm not differ by more than 75 mm [3.

  DROWSY CHAPERONE SCORE PDF

Hence, for the purpose of developing a self-consolidating concrete mixture in the laboratory, a relative measure of viscosity is useful. When performing the slump? For similar materials, asstm time period, termed T50, gives an indication of the relative viscosity of the self-consolidating concrete mixture. Special high-range water-reducing admixtures are typically used to modify the? In addition, viscositymodifying admixtures and other changes in mixture proportions and materials can also in?

No evidence of segregation and slight bleeding observed as a sheen on the concrete mass.

ASTM C1611

A slight mortar halo 10 mm [ 0. However, these values do not quantify astmm concrete property. Approved April 1, ASTM International takes no position respecting the validity of any aastm rights asserted in connection with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility.

This standard is subject to revision at any time by the responsible technical committee and must be reviewed every? Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters.

Your comments will receive careful consideration at a meeting of the responsible technical qstm, which you may attend. If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below.

Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm. Sstm rights to photocopy the standard may also be secured from the ASTM website www.